Precision Handling for Pristine Environments
Our Nitrile Cleanroom Gloves are engineered for the most demanding ISO Class 5 (Class 100) applications. Manufactured from 100% synthetic nitrile polymer, these gloves are entirely powder-free and undergo a rigorous double-chlorination and DI-water rinsing process to ensure ultra-low particulate counts. With micro-textured fingertips for superior tactile sensitivity and a secure grip, they provide the protection you need without compromising the dexterity your work requires.
- ISO Class 5 Compliant: Cleaned and processed to Level 100 standards for use in highly controlled environments.
- Advanced Purity: Double-chlorinated and rinsed in Deionized (DI) water to minimize surface ions and extractables.
- Enhanced Grip: Micro-textured fingertips provide excellent “wet or dry” grip for handling delicate components and glassware.
- Contamination Control: Vacuum-sealed in double poly bags (100 gloves per bag) to ensure integrity from our facility to your cleanroom.
- Synthetic Comfort: 100% Acrylonitrile Butadiene (Nitrile) construction offers a latex-free, durable, and comfortable fit for extended wear.
When your process leaves no room for error, choose Nitrile Cleanroom Gloves that meet the standard. Designed for pharmaceutical, semiconductor, and medical device manufacturing, these gloves act as a high-integrity barrier against contamination. They are robust enough to resist punctures yet thin enough to maintain full touch sensitivity. Available in sizes Small through X-Large to ensure a perfect, compliant fit for your entire team.
Product Specifications
Technical Data
| ESD Resistance | Decay Time | Tribo Charge | Test Method |
| < 1 x 1010 ohms / square | < 0.5 seconds | < 20 volts | ESD STM 11.11 |
| Purity Specifications | Particles | Upper Limits | Test Method |
| > 0.5 micron | < 2500 particles / cm2 | IEST-RP-CC005.2 |
| Purity Specifications | Particles | Upper Limits | Test Method |
| DIW Extractant | < 1.6 mg/g | IEST-RP-CC005.2 |
| Non Volatile Residue
(NVR) | < 3.5 mg/g | IEST-RP-CC005.2 |
| Purity Specifications | Ions (< 50 ppm) | | Test Method |
| Anions | Flouride | Chloride | IEST-RP-CC005.2 |
| Nitrite | Cations | Lithium | |
| Sodium | Potassium | Bromide | |
| Phosphate | Nitrate | Sulphate | |
| Ammonium | Magnesium | Calcium | |
| Purity Specifications | Copper Corrosion | | Test Method |
| No Visible Discoloration | | IEST-RP-CC005.2 |
Silicone oil, Amide,
Phthalate (DOP) Presence | FT-IR | | Test Method |
| Not Detected | | IEST-RP-CC005.2 |
Sizes
Length is measured from tip of middle finger to cuff; width is measurement of the cuff opening. There is a 5mm margin of error.
| Size | Length | Width |
| Small | 11.5 inches | 3.34 inches |
| Medium | 11.5 inches | 3.75 inches |
| Large | 11.5 inches | 4.15 inches |
| XL | 11.5 inches | 4.5 inches |
| 2XL | 11.5 inches | 5 inches |
Durability Details
| Durability | Tensile Strength | Elongation at Fail | Test Method |
| Befor Aging | 14 Mpa, Minimum | 500% Minimum | ASTM D-4412 and D-573 |
| After Aging | 14 Mpa, Minimum | 400% Minimum | ASTM D-4412 and D-573 |
| Freedom of Holes | | 1.5 AQL | ASTM D-5151 |
| Nominal Thickness | | 5 mil / 0.13 mm | ASTM D-3767 and D-6319 |
| Nominal Length | | 12 inches/ 305 mm | ASTM D-3767 and D-6319
|
Can’t find your specific spec? Let us do the legwork.
Navigating ISO standards and material compatibility can be a challenge. If you don’t see the exact size, material, or style of Cleanroom Apparel you need, our team is ready to help. We specialize in sourcing high-performance gear that meets your facility’s precise requirements.
Request a Custom Quote or call us at +1(937)-324-1100 to talk shop with a specialist.
Reviews
There are no reviews yet.